• Contact & Helpdesk

  • +886-2-8245-2186Weekdays: 8:30 to 18:00
  • dalu@dalu.com.tw
  • +886-2-8245-2185
Adobe

You are here: Home > Non-contact absolute position transducer(position,distance.).. > 18xx series: Profile type > Products

18xx series: Profile type

  • measurement type:

    Linear displacement

  • Input voltage:

    +24Vdc (20.4 - 28.8Vdc)

  • Input protection:

    Polarity protection up to -30Vdc, Over voltage up to 36Vdc

  • Current consumption:

    50-140mA (stroke range dependent)

  • Dielectric strength:

    500Vdc (DC ground to machine ground)

  • Output: Anolog

    0-10Vdc, 10-0Vdc dual-output, minimum load 5kΩ

  • 0(4)-20mA, 20-0(4)mA,

  • Output: Digital

    start/stop,

  • Bus(CANopen, CANbasic...)

  • Resolution:

    Analog: Inifite(restricted by output ripple)

  • Digital: Inifite(restricted by output ripple)

  • CANBus: 5um,0.5mm/s, 2um,0.2mm/s

  • Repeatbility:

    < ±0.005% of full scale

  • Non-linearity:

    < ±0.01% of full scale(maximum ±90μm)

  • Operation temp.:

    -40~75℃

  • IP rating:

    IP65/IP67(with connector)

  • Vibration rating:

    15g, 10-2000Hz / IEC standard 68-2-6

  • Shock rating:

    100g single hit per IEC standard 68-2-27

  • update rating:

    0.5ms up to1200mm

  • 1.0ms up to 2400mm

  • 2.0ms up to 4800mm

  • 5.0ms up to 7600mm